Balcony inspection and repair services in Southern California
SB-721 & SB-326 Certified

Balcony & Deck
Inspection, Repair & Waterproofing

We provide comprehensive balcony and elevated deck services for residential and multi-family buildings across Los Angeles and Orange County — from mandatory SB-721 compliance inspections to full structural repair and waterproofing.

Schedule Free Inspection (213) 583-6669
Licensed GC #1110475
SB-721 & SB-326 Certified
LA & Orange County
Free On-Site Inspection
48-Hour Scheduling

Our Balcony & Deck Services

Full-service structural solutions for elevated elements — from compliance reports to complete structural rebuilds.

SB-721 Apartment Balcony Inspections

SB-721 Apartment Balcony Inspections

Certified SB-721 balcony inspections for apartment buildings with 3+ units by a licensed General Building Contractor (CSLB #1110475).

  • Authorized general building contractor (CSLB #1110475, Class B)
  • 15% statistical sampling per Health & Safety Code §17973
  • Non-destructive borescope camera & digital moisture testing
Learn More
SB-326 HOA & Condo Balcony Inspections

SB-326 HOA & Condo Balcony Inspections

Turnkey SB-326 compliance for HOA boards and condominium associations. We coordinate licensed engineers and execute all structural repairs.

  • Licensed engineering coordination provided for HOA boards
  • 95% statistical confidence random sampling calculations
  • Reserve study integration for long-term budget planning
Learn More
Balcony Structural Repair & Reconstruction

Balcony Structural Repair & Reconstruction

Complete balcony restoration: dry rot removal, cantilever outrigger replacement, code-compliant guardrail rebuilds, stucco soffit venting, and plywood decking.

  • Load-bearing cantilever joist replacement & structural sistering
  • Code-compliant guardrail rebuilds (42" height & 200 lb load rating)
  • Stucco soffit removal, mold treatment & ventilation vents
Learn More
Balcony Waterproofing & Coating

Balcony Waterproofing & Coating

High-performance waterproofing systems, Enduro-Kote® cementitious & XL composite fiberglass coatings with custom decorative textures.

  • Enduro-Kote® Standard 3-coat heavy-duty cementitious waterproofing system
  • Enduro-Kote® XL 4-coat composite system with Chopped Strand Fiberglass Mat & 10-year warranty
  • Architectural decorative finishes: Sand Finish (Siltstone), Knockdown texture, and faux-stone/tile patterns
Learn More
Balcony Guardrails & Railing Systems

Balcony Guardrails & Railing Systems

Engineered balcony guardrail replacement and repair meeting California Building Code (CBC 1015) 42" height & 200 lb load standards.

  • California Building Code (CBC 1015) compliant 42" minimum guardrail height
  • Child-safety 4-inch sphere rule strictly engineered across all balusters and cable runs
  • 200 lb concentrated horizontal point load testing & compliance certification
Learn More
California Law

SB-721 & SB-326 Compliance Deadlines

California law requires multi-family buildings to have exterior elevated elements inspected by licensed professionals. Non-compliance can result in heavy fines and liability in the event of structural failure.

SB-721Inspections due — act now

Apartment buildings with 3+ units

SB-326Ongoing compliance required

Condominiums & HOAs

Get Compliance Inspection
Balcony inspection
4.9★ Rated Service
47+ verified client reviews

Why Property Owners Choose PiersPro

🏛️

Licensed & Insured

California GC License #1110475. Fully bonded and insured for your protection.

📋

Full Compliance Reports

Detailed inspection reports suitable for HOA records, city submission, and real estate disclosures.

🔧

Inspection + Repair

We do both — no need to hire a separate contractor if repairs are needed.

📅

48-Hour Scheduling

Fast response. Most inspections scheduled within 48 hours of first contact.

California Regulatory & Inspection Scope Disclosure

SB-721 inspections are performed under California Health & Safety Code §17973 by a licensed general building contractor with more than five years of relevant experience. SB-326 inspections under California Civil Code §5551 must be performed by a licensed structural engineer, civil engineer, or architect. We do not perform SB-326 inspections; we execute the repairs identified in the inspecting professional's report and manage the project on the association's behalf. When you work with PiersPro, we coordinate and provide a licensed engineer for your project, so you do not need to search for one yourself. We do not provide structural engineering services directly. Evaluations of structural capacity, load analysis, and stamped design documents are prepared by a licensed engineer.

Need a Balcony Inspection or Repair?

Don't wait for a structural failure. Schedule your inspection today — most appointments within 48 hours.

Schedule Free Inspection (213) 583-6669